Step
Press the Select key after selecting CLEAR CARE mode.
The LCD changes as shown in (a) ---> (b)
1
Codes for Clear Care are as follows:
2: Fuser Cleaning Roller (FC)
7: Belt Cartridge (BL)
8: Fuser Unit (FU)
9: Transfer Drum (TD)
10: Replacement Kit every 240K (OW)
Using Scroll key, select the applicable CARE code, and then
2
press Select key.
The LCD changes as shown in (b) ---> (c)
Use the Scroll key to select YES, and then press the Select
3
key (c)----->(g).
Press the Media key to clear the CLEAR CARE mode.
4
The LCD changes as shown in (h) ---> (i)
Page 6-18
6.4.3.6
Clear Care
The Care Code message displayed in the LCD can be cleared. Make sure
to replace the item displayed in the CLEAR CARE menu before using
this menu.
Table 6-9: Clear Care Procedure
Description of Procedure
Message in LCD
SERVICE MODE
(a)
CLEAR CARE
36 CLEAR CARE
(b)
No.=< FC, BL, FU, OW>
CARED FC ROLL ?
(c)
YES/NO
CARED BL UNIT ?
(d)
YES/NO
CARED FU UNIT ?
(e)
YES/NO
CARED TR DRUM ?
(f)
YES/NO
CARED 240K KIT ?
(g)
YES/NO
36 CLEAR CARE
(h)
No.=< FC, BL, FU, OW>
SERVICE MODE
(i)
TEST PRINT
magicolor 6100 Series Service Manual