Handle
Page 5-18
4.
Holding the handle provided on each side of the fuser,
remove the fuser.
When removing the fuser, keep it level so that oil doesn't
leak out. Use the siphon included with the cleaning roller
to suck out all the remaining oil in the fuser. After
siphoning, fill the oil pan with paper or tissue to ensure
that no oil leaks out.
5.3.3.5.2
Sequence of Replacement
1.
Move the roller's tension-release levers in the direction indi-
cated by the arrow.
2.
Install the new fuser into the printer.
Roller tension-release lever
3.
Install the oil bottle and cleaning roller into the fuser.
a. After setting the fuser in place, lightly press down on the
b. Secure the fuser with the thumbscrews.
4.
After the warm-up process, clear the code "REPLACE
FUSER" by the Service Mode "CLEAR CARE" mode or via
CAUTION
Fig. 5-18
Fusing Unit
Paper Exit Unit
Fig. 5-19
unit to firmly connect to the connector of base.