Step
Select LIFE PERIOD mode.
1
The LCD changes as shown in (a) ---> (b)
Using the Scroll key, select the desired code and then
press the Select key.
2: Fuser Cleaning Roller [see (b) ---> (c)]
2
7: Belt Cartridge [see (d)]
8: Fuser Unit [see (e)]
9: Transfer Drum [see (f)]
10: 240K Replacement Kit [see (g)]
Use the Scroll key to designate or change the desired
digit.
Use the Select key to input values to the blinking digit.
3
After the new values are defined, use the scroll key to
move the cursor to SET displayed in the LCD, and then,
press the Select key to register the set value.
Press the Media key to complete the setting work.
The LCD changes as shown in (g)
4
Press the Media key one more time to return to
FACTORY MODE.
The LCD changes as shown in (g) ---> (h)
magicolor 6100 Series Service Manual
6.4.3.8.5
Life Period Set
Note: These are factory settings and should not be changed.
The replacement life of the periodical replacement parts can
be set.
Table 6-16: Life Period Set Procedure
Description of Procedure
Message in LCD
39 FACTORY MODE
(a)
LIFE PERIOD SET
44 LIFE PERIOD
(b)
No.=< 1 2 3 4 5 6 7 8 9 >
PERIOD FC ROLL
(c)
018000 P SET
PERIOD BL UNIT
(d)
120000 P SET
PERIOD FU UNIT
(e)
100000 P SET
PERIOD TR DRUM
(f )
600000 P SET
PERIOD 240K UNIT
(g)
240000 P SET
44 LIFE PERIOD
(h)
No.=< 1 2 3 4 5 6 7 8 9 >
Page 6-25