Step
Select TOTAL PAGE SET.
1
The LCD changes as shown in (a) ---> (b)
Select the type of page (for example, TOTAL PAGE, LFU
PAGE, or DPL PAGE).
2
The LCD changes as shown in (b) ---> (c)
Use the Scroll key to designate or change the desired digits.
Use the Select key to select a digit.
After selecting the values to be set, use the scroll key to
3
move the cursor to SET displayed in the LCD, and then
press the Select key to select the value.
The LCD changes as shown in (c) ---> (d)
Page 6-34
6.4.3.8.6.8
Table 6-25: Total Page Reset Procedure
Description of Procedure
Total Page Reset
Note: These are factory settings and should not
be changed.
This mode can reset the number of total pages
in NVRAM whenever executing NVRAM
INITIAL or replacing the MCTL PWB.
Message in LCD
39 FACTORY MODE
(a)
47 TOTAL PAGE
(b)
47 TOTAL PAGE
(c)
47 LFU PAGE
(c)
47 DPL PAGE
(c)
39 FACTORY MODE
(d)
magicolor 6100 Series Service Manual
TOTAL PAGE SET
TOTAL /LFU/DPL
P
or
P
or
P
DP CHECK