1. Holding the knob and band located on the top of the drum cleaner,
remove the drum cleaner. Pull both ends of the handle upward, and
then remove the drum cleaner shaft from the bearing at the engine
sides (see Fig. 5-25).
Drum Cleaner
Fig. 5-25
2.
Clean the area where the drum cleaner will be mounted.
3.
Install a new drum cleaner in the printer (see Fig. 5-26). Push
the drum cleaner into the printer, having both ends meet the
bearing at the engine side.
Spring
Shaft of Drum Cleaner
Fig. 5-26
4.
Close the top door.
5.
Turn on the power.
6.
Upon completion of warming-up, clear the code "120K
CHECKUP" with the Service Mode CLEAR CARE Mode or
via "ADMINISTRATION/CONSUMABLES/PM SERVICE/
120K PM SERVICE."
Shaft of Counter