Error Code
Part Name
Is the connector CN4 connected properly
between the D-FAN and Relay P.W.B ?
Is CN1 of Relay P.W.B connected
properly with D-CN2 of DUPL P.W.B ?
No
Interlock Switch
SW2
SW1
CNDU
magicolor 6100 Series Service Manual
P6
D-FAN ERROR
Checkthe connection of harness.
Yes
Yes
Is the code P6 cleared ?
No
Replace the D-Fan Motor.
Is the code P6 cleared ?
No
Replace the DUPL P.W.B.
Is the code P6 cleared ?
Yes
Completed
SW3
SW4
DPCN4
DPCN1
DUP P.W.B
DPCN2
DPCN6
No
Yes
Yes
D-FAN
CN2
CN3
CN4
CN5
Relay P.W.B
CN1
Fig. 8-60
Connect the harness
properly.
Connect the harness
properly.
CN6
CN7
CN8