7.5.3
Page 7-54
Interlock Switch (Left Access Plate area)
7.5.3.1
Tools
#1 Phillips Screwdriver
7.5.3.2
Disassembly Procedures
(see Fig. 7-48)
1. Remove the left side cover (see section 7.1.3).
2. Remove the high voltage power supply (see section 7.2.6).
3. Remove the transfer drum (see section 7.6.3).
4. Remove two set screws (ST3x6) from the transfer electrode base.
5. Remove the transfer electrode base from the frame.
6. Disconnect all the harness connectors from the interlock switch.
7. Remove the interlock switch from the transfer electrode base.
Interlock Switch
7.5.3.3
Assembly Procedures
1. Install a new interlock switch to the transfer electrode base.
2. Reassemble in reverse order of disassembly.
The interlock switch is important for safety. After instal-
lation, verify that the switch operates normally.
Transfer Electrode Base
Paper Exit Frame Ass'y
Fig. 7-48
CAUTION: