OPC Belt
Page 5-10
5.2.2.5
Cleaning of the Belt Cartridge
Belt Cartridge shall be cleaned according to the periodic maintenance
cleaning cycle presented in Table 5-3.
Do not expose the OPC belt to light of more than 800
Lux (ordinary office light) for more than two minutes. Do
not touch the surface of the OPC belt.
Supplies:
1. Lint-free cotton cloth (2 ~ 3)
Cleaning Procedures (see Fig. 5-7):
1. Turn off the power supply switch.
2. Open the top door.
3. Open the front door.
4. Release the belt cartridge lock levers.
5. Pull out the belt cartridge.
6. Clean the belt cartridge with a cotton cloth.
a. Clean the rear side of the belt cartridge.
b. Clean the corona wire with the wire brush. Slide the brush in the
direction of the arrow several times.
c. Clean the belt cartridge case.
Cleaning Area
Belt Cartridge Case
WARNING
Corona Wire
Corona Case
Fig. 5-7
Wire Brush
magicolor 6100 Series Service Manual