Step
Select FU CHECK.
1
The LCD changes as shown in (a) ---> (b)
Once FU CHECK is selected, the fuser unit starts to
heat up and checks the availability of fuser oil. If oil is
2
available in the fuser unit, "GOOD" is displayed in the
LCD, otherwise, "FAIL" is displayed.
The LCD changes as shown in (b)
Press the Media key to stop the FU CHECK mode.
3
The LCD changes as shown in (b) ---> (c)
magicolor 6100 Series Service Manual
6.4.3.8.3
FU Check
Availability of oil in the fuser unit can be confirmed.
Table 6-14: FU Check Procedure
Description of Procedure
Message in LCD
39 FACTORY MODE
(a)
FU CHECK
43 FU CHECK
(b)
OIL:GOOD
39 FACTORY MODE
(c)
DP CHECK
Page 6-23