7.7.2
Oil Bottle
F Cover (L)
Page 7-82
Oil Pan Unit
7.7.2.1
Tools
Phillips Screwdrivers #1 and #2
7.7.2.2
Disassembly Procedures
(see Fig. 7-73)
1. Remove the fuser from the printer.
2. Remove the oil bottle and cleaning roller.
3. Remove two set screws (ST3x6) from the oil pan unit.
4. Remove the oil pan unit from the fuser.
5. Remove the oil pan unit making sure that no oil spills out of the oil
pan. Lay the oil pan unit flat.
Cleaning Roller
Oil Pan Unit
7.7.2.3
Assembly Procedures
1. Prepare a new oil pan unit.
2. Install the new oil pan unit onto the fuser.
3. Reassemble in reverse order of disassembly.
Fuser Unit
Fig. 7-73
Cover (B)
Lamp
F Cover (R)