MINOLTA-QMS magicolor 6100 Series Service Manual page 383

Table of Contents

Advertisement

Error Code
Part Name
Is the connector CN3 connected properly
between the D-SOL and Relay P.W.B ?
Is the CN1 of Relay P.W.B connected
properly with D-CN2 of DUPL P.W.B ?
No
SW2
SW1
CNDU
magicolor 6100 Series Service Manual
P3
D-SOLENOID ERROR (L)
Check the connection of harness.
Yes
Yes
Is the code P3 cleared ?
No
Replace the D-Solenoid
Is the code P3 cleared ?
No
Replace the DUPL P.W.B.
No
Is the code P3 cleared ?
Yes
Completed
Interlock Switch
SW3
SW4
DPCN4
DPCN1
DPCN2
DPCN6
DUP P.W.B
No
No
Yes
Yes
DSOL (L)
2
CN2 CN3 CN4 CN5 CN6
CN1
Relay P.W.B
Fig. 8-58
Connect the harness
properly.
Connect the harness
properly.
CN7
CN8
Page 8-69