8.2.2
magicolor 6100 Series Service Manual
Persistent Operator Call Error Code Resolutions
Normally, the operator call can be cleared by the performing the applicable counter-
measures listed in Table 8-1. If not cleared, the printer engine may have a failure.
Check and implement the appropriate countermeasures in accordance with the fol-
lowing procedures.
Note:
If you get persistant errors, reboot the printer in service mode and use the flow
charts in this section to troubleshoot using the MCTL error codes. The MCTL error
codes are found to the left of the controller codes in the first step of the flow
charts.
Fig. Number
MCTL Code
8-2
8-3
8-4
8-5
8-6
8-7
8-8
8-9
8-10
8-11
8-12
8-13
8-14
8-15
8-16
8-17
11
PUT 'SIZE' IN ANY BIN
11
CHECK MEDIA
11
NO MEDIA UPP/LF1/LF2
11
CHK MEDIA FOR DUPLEX
12
ADJUST 'n' BIN
12
OUTPUT BIN FULL
13
'X' TONER LOW/EMPTY
14
CHECK WASTE TONER
14
FUSER OIL LOW/EMPTY
14
CHECK CLEANING ROLLER
MISPRINT
15
PAPER/NOPRQ/MEDIA/DUPLEX
16
ALIGN TONER CG Y/M/C/K
16
ALIGN FU UNIT
16
ALIGN BELT CG
16
ALIGN FUSER CL ROLLER
16
ALIGN TR ROLLER