12
Is the connection between Paper Size Sensor
and IOD1 disconnected?
Check and replace associated wiring and hardware.
No
magicolor 6100 Series Service Manual
Message "ADJUST 'n' BIN" displayed.
Check Paper Cassette.
Is Paper Size Sensor Lever damaged ?
No
Check Paper Size Sensor (PSU).
Is PSU properly installed or damaged ?
No
Is Paper Size Sensor disconnected?
No
No
Replace Paper Size Sensor (PSU) .
Is Error Code 12 cleared?
No
Replace IOD1 P.W.B.
Is Error Code 12 cleared ?
No
Is Error Code 12 cleared ?
Yes
Complete
Yes
Replace the Paper Cassette.
Yes
Replace the PSU.
Yes
Yes
Yes
Yes
Fig. 8-6
Connect the connector.