8.5.20 Insufficient Gloss
magicolor 6100 Series Service Manual
8.5.20.1 Phenomenon
Gloss of the print
is not sufficient as shown in the print sample at the upper-right corner.
8.5.20.2 Main Causes
1. Cleaning roller is stained.
2. Fuser roller is deteriorated.
Cleaning
Roller
Fuser
8.5.20.3 Countermeasures
1. Replace the cleaning roller (see section 3.3.1).
2. Replace the fuser unit (see section 5.3.3).