MINOLTA-QMS magicolor 6100 Series Service Manual page 266

Table of Contents

Advertisement

7.5.14 Cleaning Roller Sensor CRS
When installing the connector onto the cleaning roller sensor, do not
apply any excessive force to the sensor connector (Print P.W.B.).
Page 7-66
7.5.14.1 Tool
#1 Phillips Screwdriver
7.5.14.2 Disassembly Procedures
(see Fig. 7-59)
1. Open the paper exit cover.
2. Remove the paper exit unit (see section 7.6.6).
3. Remove the harness cover.
4. Remove one set screw (ST3x6) from the sensor base.
5. Disconnect the connectors from the cleaning roller sensor.
6. Remove the cleaning roller sensor.
a. Put your finger in the rear side of installation base, and then,
unhook the base.
b. Remove the sensor.
Hook C
Connector
Cleaning Roller Sensor
7.5.14.3 Assembly Procedures
1. Install the sensor onto the base.
2. Connect the harness connectors to the cleaning roller sensor.
3. Confirm that hooks a, b, and c are hooked firmly onto the sensor
base.
4. Reassemble in reverse order of disassembly.
Harness Cover
Sensor Base
Hook B
Hook A
Fig. 7-59
CAUTION:
magicolor 6100 Series Service Manual

Advertisement

Table of Contents
loading