Introduction
Source #1
Source #2
Source #3
Source #x
Always #1
Always #y
Trigger #1
Trigger #z
22.2.2 Features
The DMAMUX module provides these features:
• Up to 63 peripheral slots and up to six always-on slots can be routed to 16 channels.
• 16 independently selectable DMA channel routers.
• The first two channels additionally provide a trigger functionality.
• Each channel router can be assigned to one of the possible peripheral DMA slots or
to one of the always-on slots.

22.2.3 Modes of operation

The following operating modes are available:
• Disabled mode
356
DMAMUX
Figure 22-1. DMAMUX block diagram
KV4x Reference Manual, Rev. 2, 02/2015
Preliminary
DMA channel #0
DMA channel #1
DMA channel #n