FIGURE 5
2. Install the replacement starter with the
solenoid located on the underside of the
starter motor as shown on
3. Hand tighten the three mounting nut.
Flange nut M12 p/n 990942 qty: 3
4. Once the starter is properly seated on the
flywheel
housing,
mounting nuts to al torque of 44 lbf-ft.
INSTALLATION OF CIRCUIT 0C
5. Connect the ground cable (circuit 0C) to
the ground terminal first. Make sure the
ground cable extends vertically downward
from the terminal as shown on
6. Secure the ground cable lug with the nut
previously removed at step 1-a. Tighten to
a torque of 22 lbf-ft.
M12 hex nut p/n 983717
.
FIGURE 8
torque
the
three
.
FIGURE 9
MI16-16 / Page 4 / 6
FIGURE 6
FIGURE 7
FIGURE 8
FIGURE 9
<QF7720955 rev 2>