PREVOST H3-41 Maintenance Manual page 641

Hide thumbs Also See for H3-41:
Table of Contents

Advertisement

Section D Sika Primer 215
3. Allow drying
Mandatory
Before applying any other
product
PREPARATION OF FIBERGLASS
1. Clean using anti-silicone (refer to Section A).
2. Apply Sika 205 (refer to Section B).
Section B Sika 205
2. Allow drying
Minimum
Mandatory
time
After 2 hours : Reactivate surface with Sika 205
Before applying any other
product
1.
Shake bottle to mix product
2.
Apply a thin layer
215
Minimum time : 20 minutes
After 2 hours : Remove dust using damp cloth (pure water)
If surface seems dusty, dust using damp cloth.
If surface seems greasy or with finger marks, reactivate with Aktivator.
1.
Apply
CHIX cloth
- For a smooth surface (aluminum, stainless, steel,
fiberglass (gelcoat side), etc.):
- For a porous surface (fiberglass (non gelcoat side),
etc.)
If surface seems dusty, greasy or with finger marks, start
operation again.
PA1621 Maintenance Manual All Series
SECTION 18a: H3 SERIES BODY
CHIX cloth
2 minutes
10 minutes
|
Revised Sept 2019
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H3-45H3-45 vipX3-45X3-45 vip

Table of Contents