Electric Awning Window; Operation - PREVOST H3-41 Maintenance Manual

Hide thumbs Also See for H3-41:
Table of Contents

Advertisement

(shake well before applying). Let dry 5-6
minutes minimum but no more than 8 hours.
CAUTION
There must be absolutely no silicone on glass
or channel or Sikaflex 255 FC will not stick.
6. Put masking tape on the inner and outer
contour of the window opening on the
structure, approximately 1/16" (1,5 mm) from
the edges of the contour.
7. Install Tremshield tape around the sealing
surface of the window opening.
FIGURE 40: ADHESIVE-MOUNTED WINDOW
8. Apply a generous bead of Sikaflex-255 FC
polyurethane
adhesive
surface around the window opening from
outside the vehicle.
NOTE
To ease applying of Sikaflex 255 FC, it may be
heated to 86° F (30°C).
NOTE
Bead should touch the side surface of the
window opening.
9. Place shims correctly, and position window
glass in the opening. Press firmly and
evenly. Excess adhesive should flow out
from behind glass.
NOTE
Add adhesive in areas where overflow is
minimal or if air bubbles are present.
10. Smooth the adhesive joint using your finger
(wear vinyl gloves).
18081
on
the
sealing
Remove excess
PA1621 Maintenance Manual All Series
SECTION 18a: H3 SERIES BODY
material around both sides of the window as
soon as possible before adhesive dries.
NOTE
Remove most of the adhesive from the
scraper or trowel with a rag, and then dip tool
in solvent after each use for cleaning.
CAUTION
Never use solvents to clean excess adhesive.
11. Remove masking tape at once, clamp
window glass suitably and let dry overnight
or at least 8 hours.
12. Spraying pure water on the joint will
accelerate the drying process.

17. ELECTRIC AWNING WINDOW

The electric awning windows are connected
directly on the batteries 24 V DC terminal block.
As a result, they can be operated regardless of
the state open or close of the master switch.
However, the circuit is protected with fuse F41
(10A) located in the front service compartment.

17.1 OPERATION

Opening sequence: switch is set to the OPEN
position. Window latch solenoid SOL1-A and
SOL1-B are turned on along with M1 window
motor. Once the latch is open, proximity switch
PROX1 is de-activated, turning sol1-A and
SOL1-B off.
Closing sequence: switch is set to the CLOSE
position, turning on relay R1 which turns on M1
in reverse polarity, closing the window. Once the
window is closed, PROX1 is activated, turning on
SOL1-A and SOL1-B in reverse polarity latching
the window closed.
|
Revised Sept 2019
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H3-45H3-45 vipX3-45X3-45 vip

Table of Contents