SECTION 18a: H3 SERIES BODY
FIGURE 69: DOOR LATCHES ADJUSTMENT
27. CONDENSER DOOR ADJUSTMENT
1. Open the condenser door.
2. Loosen the nuts (1, Figure 70) holding the
hinge (3, Figure 70) to hinge attachment (4,
Figure 70). Loosening nuts (1, Figure 70)
allows the condenser assembly to be shifted
"LEFT or RIGHT" and "UP or DOWN".
3. Adjust condenser assembly position at the
hinge.
4. Tighten the nuts.
3
2
1
FIGURE 70: CONDENSER DOOR
66
PA1621 Maintenance Manual All Series
4
|
Revised Sept 2019
5. Loosen bracket nuts holding the panel to
condenser. Panel (6, Figure 70) may be
shifted "IN or OUT", "LEFT or RIGHT" and
"UP or DOWN".
6. Adjust condenser panel at brackets (2,
Figure 70) and (5, Figure 70).
7. Tighten the nuts.
8. Respect the required gap between exterior
finishing panels (Figure 52).
9. Check that the door swings freely and closes
properly. It may be necessary to adjust the
door latch to get proper fit and operation.
5
6
7
8
D280201