1.

TORQUE TABLES

1.1

HIGH CAPACITY COMPRESSOR (CENTRAL HVAC SYSTEM)

HIGH CAPACITY COMPRESSOR (CENTRAL HVAC SYSTEM)
No
1
Compressor flange connection screws
2
Compressor discharge & suction port screws
3
Compressor mounting bolts
4
Support arm to compressor screws
5
Clutch to compressor screws
6
Clutch pulley to compressor shaft screw
7
Compressor shut-off valve backseat position
8
Compressor shut-off valve frontseat position
9
Magnetic drain plug
10
Oil fill hole plug
11
Service port 7/16-20 UNF
SECTION 22: HEATING AND AIR CONDITIONING
22378_1
22406
DESCRIPTION
PA1621 Maintenance Manual All Series | Revised February 2019
TORQUE
31-35 lb-ft (42-47 Nm)
38-42 lb-ft (52-57 Nm)
82 lb-ft (111 Nm)
38-42 lb-ft (52-57 Nm)
20-24 lb-ft (27-33 Nm)
58-62 lb-ft (79-84 Nm)
12 lb-ft (16 Nm) max
21 lb-ft (28 Nm) max
37-52 lb-ft (50-71 Nm)
15-17 lb-ft (20-23 Nm)
7.5 lb-ft (10 Nm) max
5
22379
22407