SECTION 18b: X3 SERIES BODY
5. To adjust door depth, loosen the screws
fixing the hinge to frame assembly and slide
the hinge horizontally to move the door in or
out. Depth should be calculated at 29mm +/-
2mm measured from bus frame out or 5mm
+1mm if measurement is taken from small
square tube on frame.
6. Tighten the hinge screws.
7. Make final adjustment of door position and
evenness with reference to adjacent panels
and doors as required.
8. Checks handle adjustment. Handle must
remain tight against its plastic housing.
NOTE
Adjustment is made by moving UP or DOWN
the lock plates.
136
PA1621 Maintenance Manual All Series | Revised Sept 2019
9. Make sure that skid bar only touches slightly
bus structure at bottom. The door should not
move up when closing.