PREVOST H3-41 Maintenance Manual page 276

Hide thumbs Also See for H3-41:
Table of Contents

Advertisement

RING CABLE LUGS
Figure 16: Cable lugs must be closed type, crimped or welded.
Ring cable lugs should not be distorted.
Ring cable lugs should not suffer strains that can deform.
Ring cable lugs must be installed with smooth washers and nuts to prevent damage to the cable lug
when tightening.
Figure 17: Power cable shouldn't be bent just next to the cable lug. Angled cable lugs are used to avoid
mechanical stress.
Figure 18: When several terminals are connected on a single stud terminal, the largest cable lug must be
placed first, followed by the second larger and so on. Cable lugs should be distributed around the stud
terminal in a way that no cable lug is distorted when tightening the nut.
MI15-24B / Page 8 / 14