FUNCTION
PID/SID
Sensor
position of
the clutch
(SEPoC and
SEPoCINV)
Sensor
position of
the clutch
(SEPoC and
SEPoCINV)
Sensor
position of
the clutch
(SEPoC and
SEPoCINV)
ERROR
FMI
J1587
range
Deactivate: The
difference
between clutch
positions
indicated by the
sensor signal
(SEPoC) and the
inverted sensor
signal ( SEPoC
INV) is normal
Activate:
Sensor signal is
short circuit to
Ubatt or sensor
supply, when at
Voltage
least one of the
above normal
FMI3
sensor signals is
or shorted
above normal
high
range.
Deactivate: No
sensor signal is
above normal
range
Activate: 1.
Open circuit on
any of the
sensor signals is
detected when:
one of the
sensor signals is
within normal
range and the
other sensor
signal is below
normal range
Current below
2. Open circuit
FMI5
normal or
on ground,
open circuit
detected when
both the sensor
signals are
within the normal
range and the
sum of the
sensor signals is
above a specific
value
Deactivate: No
activation
condition is no
longer fulfilled
Activate: Both
sensor signals
are below
normal when:
1. Status of the
sensor ASIC
reports internal
Faulty device
FMI12
fault on the
or component
sensor, or
2. Short circuit to
Gnd on any of
the sensor
signals, or
3. Open circuit
on supply, or
PA1621 Maintenance Manual All Series | January 2017
SECTION 07: TRANSMISSION
CONDITION
SYMPTOM
Yellow lamp is
sent
Reduced clutch
performance
Reduced
gearbox comfort
at start and
marshalling
Gear changes
are slow
Yellow lamp is
sent
Reduced clutch
performance
Reduced
gearbox comfort
at start and
marshalling
gear changes
are slow
Yellow lamp is
sent
Reduced clutch
performance
Reduced
gearbox comfort
at start and
marshalling
gear changes
are slow
COMMENT
sensor signal and the
sensor supply, they will
follow the nominal relation
(Usepoc + Usepoc_inv) /
Usepoc5V = 100%
The PID 33 fault code
should not be set if there is
an active fault code on the
clutch position sensor
supply (PPID 54)
The PID 33 fault code
should not be set if there is
an active fault code on the
clutch position sensor
supply (PPID 54)
The PID 33 fault code
should not be set if there is
an active fault code on the
clutch position sensor
supply (PPID 54)