Figure 19: No exposed or broken copper strands.
A shrink tubing (or fabric tape) should cover the copper strands.
•
Ensure that the power cables and ground wire are not stretched tight.
•
Ensure that the cable lugs are still properly crimped on the copper conductor, that the conductor
•
strands are not broken so that the power cable retain its capacity and ensure unrestricted current flow.
BATTERY CABLES
Battery interconnection cables must be checked too :
•
‒
Ensure the cables are properly fastened to battery posts and that the cables are in good condition
(consult battery manufacturer documentation for appropriate tightening torque).
‒
No corroded or cut copper strands. No apparent copper strands. Protective sheath in good condition,
no cuts, no rubbing against metal edges.
Figure 20: battery bank
MI15-24B / Page 9 / 14