PREVOST H3-41 Maintenance Manual page 951

Hide thumbs Also See for H3-41:
Table of Contents

Advertisement

Hot water circulating pump
Make ................................................................................................................................................. AMETEK
Flow ..................................................................................................................................................... 15 gpm
Inlet/outlet OD ........................................................................................................................................... 3/8"
Main expansion valve
Make ......................................................................................................................................... Emerson-Alco
Preheating system
Make ............................................................................................................................................Eberspächer
Type ............................................................................................................................................ Hydronic L-II
Model .......................................................................................................................................... Hydronic L30
Capacity ................................................................................................................................................ 30 kW
Heating medium .................................................................................................................................. Coolant
Rated voltage .................................................................................................................................... 24 V DC
Operating voltage ......................................................................................................................... 20-30 V DC
Electric power consumption (without coolant recirc. pump) ............................................................. 105 watts
Fuel consumption ....................................................................................... 3.65 liters/hr (0.96 US gallons/hr)
Weight ............................................................................................................................. Approx 18kg (40 lb)
Dimensions (L x H x W) .......................................... 600mm x 222mm x 230mm (23.62 in x 8.74in x 9.05in)
SECTION 22: HEATING AND AIR CONDITIONING
PA1621 Maintenance Manual All Series | Revised February 2019
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H3-45H3-45 vipX3-45X3-45 vip

Table of Contents