Serial port
Parity: None
n
Stop bits: 1
n
Flow control: None
n
Escape sequence: None
n
History size: 0
n
Exclusive access: disabled
n
Idle timeout: 0 m
n

Configure Login mode

Login mode allows the user to log into the device through the serial port.
To change the configuration to match the serial configuration of the device to which you want to
connect:
  WebUI
1. Log into the Connect EZ WebUI as a user with Admin access.
2. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.
Note
You can also configure the serial port by using Device Configuration > Serial. Changes
made by using either Device Configuration or Serial Configuration will be reflected in both.
3. Click the name of the port that you want to configure.
The serial port is enabled by default. To disable, toggle off Enable.
4. For Mode, select Login.
5. Enable Altpin to use the Altpin feature. Altpin is disabled by default.
This feature should be enabled when you are using a modem and an 8-pin cable and you need
CD (Carrier Detect). When enabled, the DTR on pin 1 drives DCD.