Serial port
iii. Set the host name or IP address of the remote site to which data should be sent:
(config serial port1 udp destination 0)>hostname hostanme-or-IP-
address
(config serial port1 udp destination 0)>
iv. Set the port number of the remote site to which data should be sent:
(config serial port1 udp destination 0)> port port
(config serial port1 udp destination 0)>
21. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
22. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure Modbus mode

Modbus mode allows you to use the serial port for Modbus. See
To change the configuration to match the serial configuration of the device to which you want to
connect:
  WebUI
1. Log into the Connect EZ WebUI as a user with Admin access.
2. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.
Note
You can also configure the serial port by using Device Configuration > Serial. Changes
made by using either Device Configuration or Serial Configuration will be reflected in both.
Digi Connect EZ 4/4i User Guide
Configure Modbus mode
Modbus
gateway.
201