2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Enable the telnet service:
(config)> service telnet enable true
(config)>
4. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
5. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Configure the service
  WebUI
1. Log into the Connect EZ WebUI as a user with full Admin access rights.
2. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click Services > telnet.
4. (Optional) For Port, enter the port number for the service. Normally this should not be
changed.
5. Click Access control list to configure access control:
To limit access to specified IPv4 addresses and networks:
n
a. Click IPv4 Addresses.
b. For Add Address, click .
c. For Address, enter the IPv4 address or network that can access the device's telnet
d. Click  again to list additional IP addresses or networks.
To limit access to specified IPv6 addresses and networks:
n
a. Click IPv6 Addresses.
b. For Add Address, click .
Digi Connect EZ 4/4i User Guide
service. Allowed values are:
A single IP address or host name.
l
A network designation in CIDR notation, for example, 192.168.1.0/24.
l
any: No limit to IPv4 addresses that can access the telnet service.
l
Configure telnet access