Serial port
For rts_post_delay, enter the amount of time RTS is deasserted before completing
l
data transmission. The time is measured in milliseconds. The default is 0ms:
rs-422
n
Enable Termination if you want to enable electrical termination on this serial port.
l
rs-485
n
Enable termination if you want to enable electrical termination on this serial port:
l
Enable full_duplex if you want to enable full duplex communication on this serial
l
port:
The default is rs-232.
7. (Optional) Set a label that will be used when referring to this port.
(config)>path-paramlabel label
(config)>
8. Set the baud rate used by the device to which you want to connect:
(config)>path-parambaudrate rate
(config)>
9. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits bits
(config)>
10. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity parity
(config)>
Allowed values are:
even
n
odd
n
none
n
The default is none.
Digi Connect EZ 4/4i User Guide
(config)> serial port1 "rts_pre_delay value
(config)>
(config)> serial port1 rts_post_delay value
(config)>
(config)> serial port1 termination true
(config)>
(config)> serial port1 full_duplex true