Sub
05/08
Mode
Element
element
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Transfer
Temperature/humidity
t mode
sensor
05
Adjustmen
Process
Transfer
Temperature/humidity
t mode
sensor
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Image
Laser power
t mode
quality
adjustment
control
05
Adjustmen
Process
Image
Laser power
t mode
quality
adjustment
control
05
Adjustmen
Scanner
Scanner
t mode
05
Adjustmen
Scanner
Scanner
Image location
t mode
adjustment
e-STUDIO556/656/756/856
Item
Subitem
Code
2188
2192
2194
2196
2198
2250
2250
3009
3030
Sub-
Default
Acceptable
Details
code
value
value
Image quality open-
-
loop control
enforcement
Humidity display
60
0-100
Temperature display
22
0-50
Latest value of drum
22
0-100
temperature
Relative humidity
55
0-99
display at image
quality closed-loop
control
0
1st laser
Refer to
0-255
contents
1
2nd laser
101
0-255
Log table switching
0
for RADF copying
(color)
Primary scanning
113
0-255
direction (scan.
section)
3
RAM
Contents
M
When a service call has occurred or a warning
message (IQC/SPC) has appeared, "Image quality
control enforcement (05-2120)" should be performed
after the equipment is repaired or the cause of the error
is evaluated. In case the service call occurred or the
warning message (IQC/SPC) appeared again after the
performance of the code 05-2120, a test chart can be
printed out by temporarily using this code (05-2188) if
an image check is urgently needed.
M
The humidity of the inside of the equipment is
displayed.[Unit: RH%]
M
The temperature of the inside of the equipment is
displayed.[Unit: °C]
M
A drum surface temperature detected at the drum
surface potential sensor control is displayed.
M
A relative humidity detected at the image quality
closed-loop control is displayed.
M
When the value increases, the laser power output
increases.
<Default value>
e-STUDIO556/656: 132
e-STUDIO756/856: 101
M
When the value increases, the laser power output
increases.
Valid only for e-STUDIO756/856
0-4
SYS 0: Same log table as the one used at copying with
original glass
1: Background reproduction - Light 2
2: Background reproduction - Light 1
3: Background reproduction - Dark 1
4: Background reproduction - Dark 2
SYS When the value increases by "1", the image shifts by
approx. 0.0423 mm toward the front side of the paper.
Proc
Service
edure
UI
6
2
Yes
2
Yes
2
2
14
Yes
14
Yes
1
1
Yes

Advertisement