1430
announce-interval announce-interval-value;
[edit protocols ptp master]
Statement introduced in Junos OS Release 12.3 for ACX Series Routers.
Configure the logarithmic mean interval for the announce messages to be sent by the
2
master. This is a log
value, which means that announce messages are requested to be
sent every two seconds.
—Announce interval value for announce messages.
announce-interval-value
Range: 0 through 4
Default: 1
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
IEEE 1588v2 PTP Boundary Clock Overview on page 234
Configuring Precision Time Protocol Clocking on page 243
Configuring a PTP Master Boundary Clock on page 244
Example: Configuring a PTP Boundary Clock With Unicast Negotiation on page 250
Example: Configuring a PTP Boundary Clock on page 248