Juniper ACX1000 Configuration Manual page 1221

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
Chapter 34: Configuring Operations, Administration, and Management (OAM)
Counters
500
Policers
0
App tcam usage:
----------------
App-Name
Related-App-Name ..
-----------------------------------------------------------------
fw-l2-in
fw-semantics
Group: 14, Mode: SINGLE, Hw grps used: 1, Tcam apps: 1
Used
Tcam-Entries
200
Counters
200
Policers
100
App tcam usage:
----------------
App-Name
Related-App-Name ..
-----------------------------------------------------------------
fw-ifl-in
Tcam Resource Stage: Egress
---------------------------
Free [hw-grps: 3 out of 3]
No dynamic tcam usage
Configure additional Layer 2 services on the router.
2.
For example, add 20 more services on the router, thereby increasing the total number
of services to 120. After adding more services, you can check the status of the
configuration by verifying either the syslog message using the command
messages
, or by running the
The following is a sample syslog message output showing the TCAM resource shortage
for Ethernet-switching family filters for newer configurations by running the
messages
CLI command.
[Sat Jul 11 16:10:33.794 LOG: Err] ACX Error
(dfw):acx_dfw_check_phy_slice_availability :Insufficient phy slices to
accomodate grp:13/IN_IFF_BRIDGE mode:1/DOUBLE
[Sat Jul 11 16:10:33.794 LOG: Err] ACX Error
(dfw):acx_dfw_check_resource_availability :Could not write filter:
f-bridge-ge-0/0/0.103-i, insufficient TCAM resources
[Sat Jul 11 16:10:33.794 LOG: Err] ACX Error (dfw):acx_dfw_update_filter_in_hw
:acx_dfw_check_resource_availability failed for filter:f-bridge-ge-0/0/0.103-i
[Sat Jul 11 16:10:33.794 LOG: Err] ACX Error (dfw):acx_dfw_create_hw_instance
:Status:1005 Could not program dfw(f-bridge-ge-0/0/0.103-i)
type(IN_IFF_BRIDGE)! [1005]
[Sat Jul 11 16:10:33.794 LOG: Err] ACX Error (dfw):acx_dfw_bind_shim :[1005]
Could not create dfw(f-bridge-ge-0/0/0.103-i) type(IN_IFF_BRIDGE)
[Sat Jul 11 16:10:33.794 LOG: Err] ACX Error (dfw):acx_dfw_bind :[1000] bind
failed for filter f-bridge-ge-0/0/0.103-i
If you use the
show pfe tcam errors all-tcam-stages detail
status of the configuration, the output will be as shown below:
1024
524
1024
1024
Entries Counters Policers Precedence
500
500
0
X
Allocated
Available
512
312
512
312
512
412
Entries Counters Policers Precedence
200
200
100
show pfe tcam errors
0
0
State
0
2
OK
X
1
OK
Errors
0
0
0
State
1
OK
show log
command.
CLI command to verify the
show log
1163

Hide quick links: