ACX Series Universal Access Router Configuration Guide
show chassis alarms (MX960, MX480, and MX240 Routers showing Major CB Failure)
show chassis alarms (PTX10008 Router)
show chassis alarms (T4000 Router)
show chassis alarms (Unreachable Destinations Present on a T Series Router)
1854
A major CB 0 failure alarm occurs in the event of a bad CB (unknown or mismatched CBs
do not trigger this alarm in Junos Release OS 12.3R9 and later). Following GRES or
recovery, if the hardware issue persists, the traffic moves to the good CB and continues.
If the alarm was triggered by something transient like a power zone budget on GRES,
bringing the CB back online can clear the alarm. Otherwise, replace the bad CB. Note
that fabric link speed is not impacted by an offline SCB. The alarm migh be raised on
CB0, CB1, and CB2.
user@host> show chassis alarms
6 alarms currently active
Alarm time
2014-10-31 16:49:41 EDT
2014-10-31 16:49:41 EDT
2014-10-31 16:49:31 EDT
2014-10-31 16:49:31 EDT
2014-10-31 16:49:31 EDT
2014-10-31 16:49:31 EDT
user@host>show chassis alarms
12 alarms currently active
Alarm time
2017-05-09 01:38:55 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
2017-05-05 06:49:57 PDT
user@host> show chassis alarms
9 alarms currently active
Alarm time
2007-06-02 01:41:10 UTC
2007-06-02 01:41:10 UTC
2007-06-02 01:41:10 UTC
2007-05-30 19:37:33 UTC
2007-05-30 19:37:29 UTC
2007-05-30 19:37:13 UTC
2007-05-30 19:37:13 UTC
2007-05-30 19:37:03 UTC
2007-05-30 19:37:03 UTC
user@host> show chassis alarms
10 alarms currently active
Alarm time
Class
Description
Major
PEM 3 Not OK
Major
PEM 2 Not OK
Major
CB 0 Failure
Minor
CB 0 Fabric Chip 0 Not Online
Minor
CB 0 Fabric Chip 1 Not Online
Minor
Backup RE Active
Class
Description
Minor
Loss of communication with Backup RE
Major
FPC 5 LCPU Temp Sensor Access Failed
Major
FPC 5 PE2 Temp Sensor Hot
Major
FPC 5 PE1 Temp Sensor Hot
Major
FPC 5 PE0 Temp Sensor Hot
Major
FPC 5 Exhaust-C Temp Sensor Hot
Major
FPC 5 Exhaust-B Temp Sensor Hot
Major
FPC 5 Exhaust-A Temp Sensor Hot
Major
FPC 5 Intake-B Temp Sensor Access Failed
Major
FPC 5 Intake-A Temp Sensor Access Failed
Major
Fan Tray 0 Fan 5 running at lower speed
Major
Fan Tray 0 Fan 4 running at lower speed
Class
Description
Minor
RE 0 Not Supported
Minor
CB 0 Not Supported
Minor
Mixed Master and Backup RE types
Major
SPMB 1 not online
Minor
Front Bottom Fan Tray Absent
Major
PEM 1 Input Failure
Major
PEM 0 Not OK
Major
PEM 0 Improper for Platform
Minor
Backup RE Active