Juniper ACX1000 Configuration Manual page 1379

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Action
Copyright © 2017, Juniper Networks, Inc.
From operational mode, enter the
user@PE2> show vpls connections
Layer-2 VPN connections:
Legend for connection status (St)
EI -- encapsulation invalid
EM -- encapsulation mismatch
VC-Dn -- Virtual circuit down
CM -- control-word mismatch
CN -- circuit not provisioned
OR -- out of range
OL -- no outgoing label
LD -- local site signaled down
RD -- remote site signaled down
LN -- local site not designated
RN -- remote site not designated RM -- remote site ID not minimum designated
XX -- unknown connection status
MM -- MTU mismatch
BK -- Backup connection
PF -- Profile parse failure
RS -- remote site standby
LB -- Local site not best-site
VM -- VLAN ID mismatch
Legend for interface status
Up -- operational
Dn -- down
Instance: customer
VPLS-id: 601
Neighbor
10.255.14.217(vpls-id 601) rmt
Remote PE: 10.255.14.217, Negotiated control-word: No
Incoming label: 800001, Outgoing label: 299904
Negotiated PW status TLV: No
Local interface: vt-2/0/10.84934914, Status: Up, Encapsulation: VLAN
Description: Intf - vpls customer neighbor 10.255.14.217 vpls-id 601
user@PE3> show vpls connections
Layer-2 VPN connections:
Legend for connection status (St)
EI -- encapsulation invalid
EM -- encapsulation mismatch
VC-Dn -- Virtual circuit down
CM -- control-word mismatch
CN -- circuit not provisioned
OR -- out of range
OL -- no outgoing label
LD -- local site signaled down
RD -- remote site signaled down
LN -- local site not designated
RN -- remote site not designated RM -- remote site ID not minimum designated
XX -- unknown connection status
MM -- MTU mismatch
BK -- Backup connection
PF -- Profile parse failure
RS -- remote site standby
Chapter 35: Configuring Virtual Private LAN Service
command.
show vpls connections
NC -- interface encapsulation not CCC/TCC/VPLS
WE -- interface and instance encaps not same
NP -- interface hardware not present
-> -- only outbound connection is up
<- -- only inbound connection is up
Up -- operational
Dn -- down
CF -- call admission control failure
SC -- local and remote site ID collision
LM -- local site ID not minimum designated
IL -- no incoming label
MI -- Mesh-Group ID not available
ST -- Standby connection
PB -- Profile busy
SN -- Static Neighbor
RB -- Remote site not best-site
Type
St
Time last up
Up
Oct
9 16:29:02 2012
NC -- interface encapsulation not CCC/TCC/VPLS
WE -- interface and instance encaps not same
NP -- interface hardware not present
-> -- only outbound connection is up
<- -- only inbound connection is up
Up -- operational
Dn -- down
CF -- call admission control failure
SC -- local and remote site ID collision
LM -- local site ID not minimum designated
IL -- no incoming label
MI -- Mesh-Group ID not available
ST -- Standby connection
PB -- Profile busy
SN -- Static Neighbor
# Up trans
1
1321

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx5048Acx5096Acx500Acx1100Acx2000Acx2100 ... Show all

Table of Contents