Table 100: jnxSoamDmThresholdCfgTable (continued)
Object
1224
Object ID
Description
bJnxS oamDmMe a sur edI f dvForw ar dT hr eshol d (11)—Enabl e s
or disables measured frame IFDV forward
threshold notification. The notification is
sent immediately when the
jnxSoamDmMeasuredStatsIfdvForward
value is greater than or equal to threshold
value.
bJnxSoamDmMaxIfdvForwardThreshold(12)—Enables
or disables maximum frame IFDV forward
threshold notification. The notification is
sent immediately when the
jnxSoamDmCurrentStatsIfdvForwardMax
value is greater than or equal to threshold
value in a Measurement Interval.
bJnxSoamDmAvgIfdvForwardThreshold(13)—Enables
or disables average frame IFDV forward
threshold notification. The notification is
sent when at the end of a Measurement
Interval if the
jnxSoamDmCurrentStatsIfdvForwardAvg
value is greater than or equal to the
threshold value.
b J n x S o a m D m M a x F r a m e D e l a y R a n g e F o r w a r d T h r e s h o l d ( 1 4 ) — E n a b l e s
or disables maximum Frame Delay Range
forward threshold notification. The
notification is sent immediately when the
j n xSoamDmCurrentSta tsFrameDel a yRangeForwardMax
value is greater than or equal to threshold
value in a Measurement Interval.
b J n x S o a m D m A v g F r a m e D e l a y R a n g e F o r w a r d T h r e s h o l d ( 1 5 ) — E n a b l e s
or disables average Frame Delay Range
forward threshold notification. The
notification is sent when at the end of a
Measurement Interval if the
j n xSoamDmCurrentStatsFrameDel a yRangeForwardAvg
value is greater than or equal to the
threshold value.
b J n x S o a m D m M e a s u r e d F r a m e D e l a y B a c k w a r d T h r e s h o l d ( 1 6 ) — E n a b l e s
or disables measured backward frame
delay threshold notification. The
notification is sent immediately when the
jnxSoamDmMeasuredStatsFrameDelayBackward
value is greater than or equal to threshold
value.
b J n x S o a m D m M a x F r a m e D e l a y B a c k w a r d T h r e s h o l d ( 1 7 ) — E n a b l e s
or disables maximum backward frame
delay threshold notification. The
notification is sent immediately when the
jnxSoamDmCurrentStatsFrameDelayBackwardMax
value is greater than or equal to threshold
value in a Measurement Interval.