Juniper ACX1000 Configuration Manual page 1400

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

ACX Series Universal Access Router Configuration Guide
Table 106: Parameters for test-profile Configuration (continued)
Parameters
packet-size
bandwidth-kbps
step-percent
Table 107: Parameter for test-name configuration
Parameters
check-test-interface-mtu
destination-ipv4-address
destination-mac-address
destination-udp-port
direction
1342
Description
Size of the test packet.
The valid packet sizes are 64, 68, 72, 128, 256, 512, 768, 1024, 1280, 1518, 1522, 1600, 1728,
2496, 3584, 4016, 9104, and 9136 bytes.
Define the maximum bandwidth limit, in kilobits per second (kbps).
Range: 1,000 kpbs through 1,000,000 kbps.
Specify the step percentage for frame-loss tests.
Default: 10 percent
Range: 1 through 100 percent
Table 107 on page 1342
lists the parameters for configuring a test-name at initiator and
reflector.
Description
When the
check-test-interface-mtu
size of the test packets with the MTU size configured on the interface and the following would be
the behavior for initiator and reflector modes:
On the initiator, if the MTU size of the test packet is larger than the MTU size configured on the
interface, then the RFC2544-based benchmarking test fails to start.
On the reflector, if the test packets coming to the reflector does not confirm to the MTU size
configured on the interface, then these test packets do not get reflected and are dropped.
Specify the destination IPv4 address.
This parameter is mandatory when family
If a value is not specified, then by default 192.168.1.20 is used.
NOTE:
This parameter is not supported on ACX5048 and ACX5096 routers.
Specify the destination MAC address. For example, 0011.2233.4455.
This parameter cannot be used when family
This parameter is optional when family
0x00:0x11:0xAE:0x92:0x2F:0x28 is used.
Specify the destination UDP port number for the test frames. Default: 4041.
NOTE:
This parameter is not supported on ACX5048 and ACX5096 routers.
Specify the test direction (
egress | ingress
This parameter is mandatory for mode
parameter is configured, the parameter validates the MTU
is specified and optional when family
inet
inet
is specified.
is specified. If not specified, then the default value of
ccc
). This parameter is valid only when family
ethernet-loopback
Copyright © 2017, Juniper Networks, Inc.
is specified.
ccc
ccc