Configuring Switching Between Pseudowires Using Vpls Mesh Groups - Juniper ACX1000 Configuration Manual

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

ACX Series Universal Access Router Configuration Guide

Configuring Switching Between Pseudowires Using VPLS Mesh Groups

1276
Note the following differences for FEC 129:
Each user-defined mesh group must have a unique route distinguisher. Do not use the
route distinguisher that is defined for the default mesh group at the
routing-intances]
hierarchy level.
Each user-defined mesh group must have its own import and export route target.
Each user-defined mesh group can have a unique Layer 2 VPN ID. By default, all the
mesh groups that are configured for the a VPLS routing-instance use the same Layer
2 VPN ID, the one that you configure at the
To configure switching between Layer 2 circuit pseudowires using VPLS mesh groups,
you can do either of the following:
Configure a mesh group for each Layer 2 circuit pseudowire terminating at a VPLS
routing instance. The Junos OS can support up to 16 mesh groups on MX Series routers
and up to 128 on M Series and T Series routers. However, two mesh groups are created
by default, one for the CE routers and one for the PE routers. Therefore, the maximum
number of user-defined mesh groups is 14 for MX Series routers and 126 for M Series
and T Series routers.
Configure a single mesh group, terminate all the Layer 2 circuit pseudowires into it, and
enable local switching between the pseudowires by including the
statement at the
[edit routing-instances routing-instance-name protocols vpls
mesh-group mesh-group-name]
switching for mesh groups (except for the CE mesh group) because all of the VPLS PE
routers must be configured in a full mesh. However, local switching is useful if you are
terminating Layer 2 circuit pseudowires in a mesh group configured for an LDP signaled
VPLS routing instance.
NOTE:
Do not include the
in a full mesh VPLS network.
To terminate multiple pseudowires at a single VPLS mesh group, include the
statement:
local-switching
local-switching;
You can include this statement at the following hierarchy levels:
[edit routing-instances routing-instance-name protocols vpls mesh-group
mesh-group-name]
[edit logical-systems logical-system-name routing-instances routing-instance-name
protocols vpls mesh-group mesh-group-name]
[edit routing-instances]
hierarchy level. By default, you cannot configure local
local-switching
statement on PE routers configured
Copyright © 2017, Juniper Networks, Inc.
[edit
hierarchy level.
local-switching

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx5048Acx5096Acx500Acx1100Acx2000Acx2100 ... Show all

Table of Contents