Table 100: jnxSoamDmThresholdCfgTable (continued)
Object
j n xS o amDmT hr e shol d C f gA v gFr ameDel a yT w oW a yT hr e shol d
Copyright © 2017, Juniper Networks, Inc.
Chapter 34: Configuring Operations, Administration, and Management (OAM)
Object ID
jnxSoamDmThresholdCfgEntry 3
Description
b J n x S o a m D m A v g F r a m e D e l a y B a c k w a r d T h r e s h o l d ( 1 8 ) — E n a b l e s
or disables average backward frame
delay threshold notification. The
notification is sent when at the end of a
Measurement Interval if the
jnxSoamDmCurrentStatsFrameDelayBackwardAvg
value is greater than or equal to the
threshold value.
b J n x S o a m D m M e a s u r e d I f d v B a c k w a r d T h r e s h o l d ( 1 9 ) — E n a b l e s
or disables measured frame IFDV
backward threshold notification. The
notification is sent immediately when the
jnxSoamDmMeasuredStatsIfdvBackward
value is greater than or equal to threshold
value.
bJnxSoamDmMaxI f dvBackwardThreshol d (20)—Enabl e s
or disables maximum frame IFDV
backward threshold notification. The
notification is sent immediately when the
jnxSoamDmCurrentStatsIfdvBackwardMax
value is greater than or equal to threshold
value in a Measurement Interval.
bJnxSoamDmAvgIfdvBackwardThreshol d (21)—Enabl e s
or disables average frame IFDV backward
threshold notification. The notification is
sent when at the end of a Measurement
Interval if the
jnxSoamDmCurrentStatsIfdvBackwardAvg
value is greater than or equal to the
threshold value.
b J n x S o a m D m M a x F r a m e D e l a y R a n g e B a c k w a r d T h r e s h o l d ( 2 2 ) — E n a b l e s
or disables maximum Frame Delay Range
backward threshold notification. The
notification is sent immediately when the
j n xS oamDmC urr entS t a tsFr ameDel a yR ang eBackw ar dMax
value is greater than or equal to threshold
value in a Measurement Interval.
b J n x S o a m D m A v g F r a m e D e l a y R a n g e B a c k w a r d T h r e s h o l d ( 2 3 ) — E n a b l e s
or disables average Frame Delay Range
backward threshold notification. The
notification is sent when at the end of a
Measurement Interval if the
j n xS oamDmCurr entS ta tsFr ameDel a yRang eBackwar dA v g
value is greater than or equal to the
threshold value.
Sets the average two-way delay
threshold value that will be used to
determine if a threshold notification is
generated.