3 alarms currently active
Alarm time
2011-08-24 16:04:15 UTC
2011-08-24 16:04:14 UTC
2011-08-24 14:21:14 UTC
SNG-0:
--------------------------------------------------------------------------
NW-NG-0:
--------------------------------------------------------------------------
1 alarms currently active
Alarm time
2011-08-24 15:49:27 UTC
user@switch> show chassis alarms
6 alarms currently active
Alarm time
2010-12-02 19:15:22 UTC
2010-12-02 19:15:22 UTC
2010-12-02 19:15:14 UTC
1/5/1, 1/5/2, 1/5/3, 1/7/0, 1/7/1, 1/7/2, 1/7/3, 2/5/0, 2/5/1, ...
2010-12-02 19:15:14 UTC
1/5/1, 1/5/2, 1/5/3, 1/7/0, 1/7/1, 1/7/2, 1/7/3, 2/5/0, 2/5/1, ...
2010-12-02 19:14:18 UTC
2010-12-02 19:14:18 UTC
user@host> show chassis alarms
23 alarms currently active
Alarm time
2011-07-12 16:22:05 PDT
2011-07-12 16:22:05 PDT
2011-07-12 16:21:57 PDT
2011-07-12 16:21:57 PDT
2011-07-12 15:56:06 PDT
2011-07-12 15:56:06 PDT
2011-07-12 15:56:06 PDT
2011-07-12 15:28:20 PDT
2011-07-12 15:19:14 PDT
All PDUs installed on a PTX5000 router must be of the same type. The
Power Manager Non Operational
on a PTX5000 router.
user@host> show chassis alarms
15 alarms currently active
Alarm time
2013-03-19 23:03:53 PDT
2013-03-19 23:03:48 PDT
2013-03-19 23:03:47 PDT
Class
Description
Major
Test:fte-0/1/2: Link down
Major
Test:fte-0/1/0: Link down
Major
Test PEM 0 is not supported/powered
Class
Description
Major
Test PEM 0 is not supported/powered
Class
Description
Major
Fan Tray Failure
Major
Fan Tray Failure
Minor
Check CB 0 Fabric Chip 1 on Plane/FPC/PFE: 1/5/0,
Minor
Check CB 0 Fabric Chip 0 on Plane/FPC/PFE: 1/5/0,
Major
PSU 1 Output Failure
Minor
Loss of communication with Backup RE
Class
Description
Minor
No Redundant Power for Rear Chassis
Major
PDU 0 PSM 1 Not OK
Minor
No Redundant Power for Fan 0-2
Major
PDU 0 PSM 0 Not OK
Major
PDU 1 PSM 2 Not OK
Minor
No Redundant Power for FPC 0-7
Major
PDU 0 PSM 3 Not OK
Major
PDU 0 PSM 2 Not OK
Minor
Backup RE Active
alarm is raised when different types of PDUs are installed
Class
Description
Minor
No Redundant Power
Minor
Mix of PDUs
Minor
PDU 1 PSM 3 Absent