Juniper ACX1000 Configuration Manual page 1245

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Table 93: jnxSoamLmCurrentStatsTable (continued)
Object
jnxSoamLmCurrentStatsForwardAvgFlr
jnxSoamLmCurrentStatsBackwardT ransmittedFrames
jnxSoamLmCurrentStatsBackwardReceivedFrames
jnxSoamLmCurrentStatsBackwardMinFlr
jnxSoamLmCurrentStatsBackwardMaxFlr
jnxSoamLmCurrentStatsBackwardAvgFlr
Copyright © 2017, Juniper Networks, Inc.
Chapter 34: Configuring Operations, Administration, and Management (OAM)
Object ID
jnxSoamLmCurrentStatsEntry 9
jnxSoamLmCurrentStatsEntry 10
jnxSoamLmCurrentStatsEntry 11
jnxSoamLmCurrentStatsEntry 12
jnxSoamLmCurrentStatsEntry 13
jnxSoamLmCurrentStatsEntry 14
Description
Contains the average one-way frame loss
ratio in the forward direction calculated
by this MEP for this Measurement
Interval. The FLR value is a ratio that is
expressed as a percent with a value of 0
(ratio 0.00) through 100000 (ratio 1.00).
Units are in milli-percent, where 1
indicates 0.001 percent.
Contains the number of frames
transmitted in the backward direction by
this MEP. For a PM Session of type
lmLmm and lmCcm this includes
Ethernet Service Frames and SOAM PDUs
that are in a higher MEG level only. For a
PM Session of types lmSlm this includes
the count of SOAM ETH-SLM frames
only.
Contains the number of frames received
in the backward direction by this MEP.
For a PM Session of type lmLmm and
lmCcm this includes Ethernet Service
Frames and SOAM PDUs that are in a
higher MEG level only. For a PM Session
of types lmSlm this includes the count of
SOAM ETH-SLM frames only.
Contains the minimum one-way frame
loss ratio in the backward direction
calculated by this MEP for this
Measurement Interval. The FLR value is
a ratio that is expressed as a percent with
a value of 0 (ratio 0.00) through 100000
(ratio 1.00). Units are in milli-percent,
where 1 indicates 0.001 percent.
Contains the maximum one-way frame
loss ratio in the backward direction
calculated by this MEP for this
Measurement Interval. The FLR value is
a ratio that is expressed as a percent with
a value of 0 (ratio 0.00) through 100000
(ratio 1.00). Units are in milli-percent,
where 1 indicates 0.001 percent.
Contains the average one-way frame loss
ratio in the backward direction calculated
by this MEP for this Measurement
Interval. The FLR value is a ratio that is
expressed as a percent with a value of 0
(ratio 0.00) through 100000 (ratio 1.00).
Units are in milli-percent, where 1
indicates 0.001 percent.
1187