EG-200
ENGINE — EFI SYSTEM
No.I
Terminals
I
Trouble
I
STD voltage
aI
STA—E1"
I
Novoltage
I
Condition
Cranking
6 V or more
ignition Switch
AM2
,
ST2
ECU
W
K
\
ST75A
ll!
AM2£'\
30A )7,
AM2 ' g
V
A
(S )
0./'~o
(ST)
1.5/\ . Q
, (ST)
MAIN \\ |'-I A
50A
' Q
SW
I50
.OY FL
MAIN FL
-i
Battery
STA
Starter Relay
Starter
I
I
E1
ti
'1
I
Z?
I
Q
P17821
G)
ECU
I STA
There is no voltage between ECU terminals STA and E1.
® (IG SW START)
'1I
tie
'.:':
Y - @=' = ==5°
Voltmeter "»;——-"1
be-—
E 1
P00749
®
ECU
' or
-v
u '
Y
'
-r
'
..
v
L1 '
I DDUCICICIUDUDD
DUDDDD
Dflnuiinciuiiuinuu
. | - - e - - - - - . --.----our --no-!-1------en,-
-1
_
_
E 1 '7
it
Ohmmeter
Voltmeter
®
Terminal 50
T
Starter
5"'
15!)!'-r
'*1
i i i »
I
\
l
/
F|437'l
Y
Check starter
OK
Check wiring between ECU terminal STA
operation.
and ignition switch terminal ST1.
BAD
OK
BAD
Repair or replace.
Check wiring between ECU terminal E1 and body
® ground.
OK
BAD
Try another ECU.
Repair or replace.
Y
Check fusible links, battery, wiring
BAD
.
.
..
.
Repair or replace.
and ignition switch.
E
.
I OK
Check that there is voltage at terminal 50 of starter.
® (IG SW START) STD voltage: 6 - 14 V
IOK
INO
Check starter'
Check wiring between 1). ST2 and 'starter
relay, and 2). battery and starter terminal 50.