AIR CONDITIONING SYSTEM
4-7
SPECIFICATIONS
Type of air conditioner
Reheat air mix type
Standard cooling efficiency (lMACA)
5,001 kW (4,300 kcal/h, 17,062 BTU/h)
Refrigerant
R-12 (CCL 2 F 2 ) [0.74 -0.79kg (1.63 -1.74Ib)]
Type
Swash plate type MJS170-60Y
Compressor
Discharge
170 cm
3
(170 cc, 10.37 cu in)/rev.
Max. permissible speed
7,500 rpm
Type
Dry, single-disc type PMC140-1 PJ
Power consumption
40W
Magnet clutch
Type of belt
Poly V type
Pulley dia. (effective dia.)
122 mm (4.80 in)
Pulley ratio
1.11
Type
Corrugated fin type
Front area
0.142 m 2 (1.53 sq ftl
Condenser
Core thickness
26 mm (1.02 in)
Radiation area
3.43 m 2 (36.9 sq ft)
Receiver dryer
Effective inner capacity
420 cm
3
(420 cc, 25.63 cu in)
Expansion valve
Type
Automatic temperature control, internal pressure-balance type
Type
Corrugated fin type
Evaporator
Dimensions (W x H x T)
101.3 x 170 x 230 mm (3.99 x 6.69 x 9.06 in)
Fan type
Sirocco fan type
Blower fan
Outer diameter x Width
140 x 65 mm (5.51 x 2.56 in)
Power consumption
230 W at 12 V
Motor type
Magnet type
Condenser fan
(Sub fan)
Power consumption
140Wat 12 V
Fan outer diameter
280 mm (11.02 in)
Motor type
Magnet type
Radiator fan
Power consumption
140 W at 12 V
(Main fan)
Fan outer diameter
340 mm (13.39 in)
Idling speed with F .I.C.O. in operation
850
±
50 rpm
Low-pressure-switch working pressure
196
±
20 kPa (2.0
±
0.2 kg/cm 2 , 28
±
2.8 psi) ON ~ OFF
206
±
29 kPa (2.1
±
0.3 kg/cm2, 30
±
4 psi)
OFF~ON
5