Subaru XT 1988 Service Manual page 1169

Table of Contents

Advertisement

"
i
SEATS, SEAT BELTS AND INTERIOR
Timing of
Operation leading
Indication
Symptom when
Location
Probable cause
when IG. SW.
belt anchor
occurrence
to occurrence
is ON
is faulty
V
When KEY SW.
Disconnected connector
Drive door opened with
OFF
Normal operation
is ON * and IG.
(chime)
KEY SW. ON*
(key warning
SW. is ON
chime does not
operate)
Short circuit in chime
Drive door opened with
Normal operation,
circuit
KEY SW. ON*
but deterioration
or breakage in
control unit
chime circu it
S
Always
Floated GN Dwire
No motion at ali
-
No motion at atl
H
When IG. SW.
Shorted door SW.
Cause generated at belt
-
Remains at re-
is OFF
circuit
{~
-
((Ul),
anchor reverse end
verse end (lamp
(@)-(
1)**
and chime
operate)
*:
With key insterted
**:
Control unit side connector terminal No.
Operation at belt anchor failure depends on the interval from removal to reconnection of the connector.
Reconnected within 13 sec .... Belt anchor moves from forward end toward reverse end and stops after 13 sec.
Reconnected after 13 sec. or more ... Remains stationary at forward end.
In either case, it moves to reverse end and stops there if IG. SW. is turned ON, then OFF and again ON.
Fault reset
a: Reset to normal when battery is reconnected after removal of the cause.
b: Reset to normal when cause is removed.
Battery OFF is reset to normal by its reconnection.
Battery OFF*1 occurs again as it has not been corrected actually.
IG. SW. OFF is reset to normal when IG. SW. is set from ON to OFF.
IG. SW. OFF*2 occurs again as it has not been corrected actually.
c: a when IG. SW. is ON and b when IG. SW. is OFF.
27
5-3
Fault reset
b
Replace control
unit
a
b

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents