FUSIBLE LINK
Fig. 19
BODY ELECTRICAL SYSTEM
1 Terminal
2 Rubber tube
3 Glass tube
4 Core wire
Fig. 20
Designation
0.5 mm
2
Appearance
4Wf&Hf
CD
6-2
A25-550
Quantity per vehicle
If current increases beyond specified amperage, fusible metal
melts and the circuit is broken, thus protecting cable and
electrical equipment from burning.
(0.0008 sq in)
0.85 mm
2
Green
2
Red
1
No.
Item
1
Voltage drop
2
Melting
Characteristics
0.5 mm
2
(0.0008 sq in)
70mV
(0.00132 sq in)
1.25 mm
2
Black
1
(0.00194 sq in)
2.0mm
2
Blue
(0.0031 sq in)
1
a. When replacing fusible link, be sure to use one with the
specified rating.
b. Blown fusible link is caused by short circuit in the source of
electricity circuit or large amperage circuit, so certain check of
cause and/or repair is necessary.
Nominal gauge size of conductor
0.85 mm
2
1.25 mm
2
2.0 mm
2
(0.00132 sq in)
(0.00194 sq in)
(0.0031 sq in)
60mV
50mV
40mV
Voltage drop across lug terminals should be less than the above value when a 10-ampere
current flows through fusible link at room temperature.
Fusible link should
Fusible link should
Fusible link should
Fusible link should
melt within 15 seconds
melt within 15 seconds
melt within 15 seconds
melt within 15 seconds
at a current flow of
at a current flow of
at a current flow of
at a current flow of
80 amperes.
130 amperes.
190 amperes.
260 amperes.
17