4-6
HEATER AND VENTILATOR
Electrical System
An electrical system is adopted in the heater control, and is
used to open or close the mode selector shutter and internal/
external air selector shutter by util izing an electrical motor.
SPECIFICATIONS AND SERVICE DATA
SPECIFICATIONS
Item
Specifications
Condition
• Temperature difference between hot
water and inlet air: 65°C (149°F)
Heating capacity'
4.536 kW (3,900 kcal/h, 15,475 BTU/h)
• Hot water flowing volume:
360Q/h (95.1 US gal/h,
79.2 Imp gal/h)
Air flow volume
330 m
3
/h (11,700 cu ft/h)
-
Fan
I
diameter x width
140 x 65 mm (5.51 x 2.56 in)
-
Fan motor
200W
at 12.8 V magnet motor
Heater core size
200 x 159.5 x 32 x 2.0 mm
I
(length x width x th ickness
(7.87 x 6.28 x 1.26 x 0.08 in)
-
x fin pitch)
8