6.5.4 DRUM POTENTIAL SENSOR REPLACEMENT

1. Take out the drum unit. (Refer to Drum Unit Removal.)
2. Disconnect the connector [A].
NOTE: Before removing the drum potential sensor, put a few sheets of paper
between the sensor and the drum to protect the drum surface.
3. Remove the drum potential sensor [B] and the grounding plate [C] (2 screws).
4. Replace the drum potential sensor [B].
!
CAUTION
After replacing the drum potential sensor, perform the process control data
initial setting (SP mode No. 2-962).