Avaya S8700 Maintenance Manual page 637

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

VAL-BD (Voice Announcements over LAN Circuit Pack)
Table 8-552. Test #600 Congestion Query Test
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
2012
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1
FAIL
The buffer level is nearly exhausted.
2
FAIL
The VAL is congested, and no buffers are available.
1. Retry command at 1-minute intervals up to 5 times.
2. If command continues to fail, examine the VAL port measurements to
A Low processor occupancy when VAL is congested indicates circuit pack
failure.
1. If the problem persists, reset the circuit pack (reset board UUCSS).
2. If congestion recurs, replace the circuit pack.
High processor occupancy indicates the VAL is congested due to traffic load.
3
FAIL
The VAL circuit pack is not operating normally and is congested.
PASS
Hardware setting and attached cable type match VAL circuit pack
administration. The circuit pack detects no errors.
555-233-142
determine which ports are heavily utilized and the processor occupancy of
the circuit pack.
To relieve congestion in the short term, selectively busyout ports (busyout
port UUCSSpp) on the VAL circuit pack.
To achieve a more permanent resolution, it could be necessary reassign
announcements to other integrated announcement circuit packs.
Consider replacing affected VAL ports with new ports.
Continued on next page
Issue 1 May 2002
8-1333

Advertisement

Table of Contents
loading

Table of Contents