PKT-INT (Packet Interface)
Table 8-397. Test #887 Read and Clear Board Counters — Continued
Error
Test
Code
Result
Description / Recommendation
1024–
FAIL
The standby IPSI's Packet Interface circuit has bad Translation RAM
1096
locations. A MINOR alarm is generated when the number of bad locations is
from 1 and 4. A MAJOR alarm is generated if the number of bad locations is 5
or more. The MAJOR alarm prevents a planned IPSI interchange. (A planned
interchange may be administered to occur automatically every 24 hours, or it
may be requested by using the set ipserver-interface Uc command.)
1. If a MAJOR alarm is associated with this error, replace the alarmed IPSI
2. If a MINOR alarm is associated with this error, replace the alarmed IPSI
PASS
The server can communicate with the IPSI circuit pack's Packet Interface
circuit.
1. If problems are still reported on the circuit pack, check for failures using
Reset Test (#889)
The reset action initializes the Packet Interface firmware on the IPSI circuit pack
and runs a comprehensive set of diagnostic tests.
The demand reset action will abort if the specified IPSI circuit pack's Packet
Interface is in the active in-service state.
An IPSI circuit pack's Packet Interface is put in the out-of-service state
automatically if it has been reset 3 times by background maintenance within the
last 15 minutes, independent of the results of the reset action.
If the Packet Interface is on the standby IPSI, the demand reset action will run,
independent of the service state.
555-233-142
circuit pack.
circuit pack at a time that would cause the least disruption to service.
the Private Loop-around test (#885) and Maintenance Loop-around test
(#886).
Continued on next page