Maintenance Object Repair Procedure
Table 8-498. Test #844-848 Transmission Test — Continued
Error
Test
Code
Result
Description / Recommendation
1920
ABORT
No response from far end.
1. The problem is with the far-end system; a technician at the far end should
1921
ABORT
No data returned from far end.
1. The problem is with the far-end system; a technician at the far end should
1922
ABORT
Steady, unidentifiable tone from far end.
1. See actions for error code 1905.
1923
ABORT
Broadband energy detected from far end (such as voice or announcement).
1. See actions for error code 1905.
1924
ABORT
No test tone from far end
1. See actions for error code 1905.
1938
ABORT
Near-end self test failed.
1. Test the TN771 circuit packs.
1939
ABORT
Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN771 circuit packs.
1940
ABORT
Far-end noise self check failed.
1. The problem is with the far-end system; a technician at the far end should
1941
ABORT
High frequency singing return loss self check failed.
1. Test the TN771 circuit packs.
1942
ABORT
Echo return loss self check failed.
1. Test the TN771 circuit packs.
1943
ABORT
Singing return loss self check failed.
1. Test the TN771 circuit packs.
1944
ABORT
Loss self check at -16 dBm at 1004 Hz failed.
1. Test the TN771 circuit packs
1945
ABORT
Loss self check at -16 dBm at 404 Hz failed.
1. Test the TN771 circuit packs.
1946
ABORT
Loss self check at -16 dBm at 2804 Hz failed.
1. Test the TN771 circuit packs.
8-1170